⌘ K

OEE Calculation Rules

The brain: maps machine states → A/P/Q losses · defines formula & counting · per-tenant/plant override

State → OEE category mapping

drag to reclassify
Machine stateCounts asOEE factorIn denominator?
Running ทำงานuptimeYes (loss)
Abnormal stop หยุดผิดปกติA-lossAYes (loss)
Material wait รอวัสดุA-lossAConditional
Changeover เปลี่ยนรุ่นA-lossAYes (loss)
Inspection ตรวจเช็คplannedExcluded (planned)
Minor stop หยุดสั้นP-lossPYes (loss)
Speed loss ความเร็วลดP-lossPYes (loss)
Defect/rework ของเสียQ-lossQYes (loss)
Stopped (idle) หยุดไลน์A-lossAYes (loss)
Powered off ปิดเครื่องexcludedExcluded (planned)

Formula & method

OEE model
Standard · A × P × Q
Availability base
Planned production time
Performance basis
Ideal cycle time (per product)
Quality basis
Good / Total input
Good count source
PLC counter (delta)
Live preview · AOI-01
A = 412/480 min = 85.8%
P = (612×38s)/actual = 87.5%
Q = 606/612 = 99.0%
OEE = 74.3%