Astrem
Welder 07· Line B2 — Welding
WO-25809·PN-7733 Sub-assembly
STATE
DOWN
Down since 10:15 — duration
12:00
Reason not yet logged — please classify
Production · This Shift
612
Good
27
Defect
639
Total
Target 950 / shift67%
Current OEE
52.1%
A61.0%
P88.2%
Q96.8%
Target Gap · Shift A
-22.9%
Below target (75%) · recover ~12 min downtime
Bottleneck flagged
Cycle time
47.2sideal 41.7
Current draw
0.0Aideal 14.2
Vibration
0.0mm/sideal 2.1
Last 8 Hours — State Timeline + Hourly OEE
RunningIdleSetupDown
06:0007:0008:0009:0010:0011:0012:0013:0014:00
7806:00
8107:00
7608:00
7209:00
7910:00
6811:00
6512:00
5213:00
ส.ก.
Somchai K.EXPERT
Personal OEE · 7d 74.2% +1.4
Shift target
67%
Next: Changeover PN-7733 → PN-4521 in 1h 28m
Recent activity· 14
LIVE
Downtime startedDOWN10:27
Welder 07 · awaiting reason
Cycle time spike10:14
47.2s vs 41.7s ideal · +13%
Defect · Burr ×2DEFECT09:42
Somchai K. · Rework
Downtime resolved08:42
Tool change · 18m
Setup completed08:21
PN-7733 first good part OK
Operator clocked in08:03
Somchai K.
Shift A started08:00
Plant target 78%